20% OFF shipping at terrelite.it on orders over $79 + up to 10% OFF products
terrelite.it
home > Foxboro P0926KN I/A Series Datasheet & Technical Manual > Foxboro P0926KN I/A Series Datasheet & Technical Manual
download picture
Foxboro P0926KN I/A Series Datasheet & Technical ManualFoxboro P0926KN I A Series FPM Power Cable The Foxboro P0926KN, also cataloged as the P0926KN Power Cable, operates as a dedicated hardware component for electrical power distribution within Foxboro I A Series platforms. Configured as a 3 pin to 3 pin Fieldbus Power Module (FPM) cable assembly measuring 60 inches (152 cm), the hardware provides direct physical electrical execution to route internal subsystem power across modular backplane segments.
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Foxboro P0926KN I/A Series FPM Power Cable

The Foxboro P0926KN, also cataloged as the P0926KN Power Cable, operates as a dedicated hardware component for electrical power distribution within Foxboro I/A Series platforms. Configured as a 3-pin to 3-pin Fieldbus Power Module (FPM) cable assembly measuring 60 inches (152 cm), the hardware provides direct physical/electrical execution to route internal subsystem power across modular backplane segments.

Hardware Specifications

Parameter Specification
Model P0926KN
Brand Foxboro
Origin USA
Weight 0.14 kg (0.30 lbs)
Dimensions Length: 152 cm (60 in)
Operating Temp -20 to +70 deg C
Power Consumption Passive (determined by conductor current load)
Cable Type FPM Power Cable
Connector Configuration 3-pin to 3-pin
Subsystem Compatibility Foxboro I/A Series FPM / Baseplate architecture
Relative Humidity Up to 95% RH (non-condensing)
Certifications CE, UL, CSA, IEC 61131-2

Process Control & DCS Power Properties

The cable assembly incorporates three independent insulated copper conductors optimized for low-impedance DC power transmission. This wiring architecture supports direct integration with Foxboro 4-20 mA HART loop protocol environments by delivering steady backbone voltage lines to baseplate modules while maintaining high-frequency noise attenuation. The physical shielding layer preserves structural channel-to-channel isolation parameters, blocking transient voltage spikes and cross-talk from migrating along parallel data communication paths.

Frequently Asked Questions

Q: Can this power cable be disconnected while the fieldbus system is fully energized? A: No, passive power cables must not be uncoupled under active load. Disconnecting the 3-pin connector while current is flowing can induce localized electrical arcing, disrupt redundant power supply rails, and cause data state degradation across adjacent hot-swappable modules.

Q: How does the cable construction resist harsh industrial ambient environments? A: The cable insulation jacket is built to operate within temperature thresholds of -20 to +70 deg C. The polymer compound jacket resists physical deformation under localized thermal loading, mechanical bending stress, and chemical outgassing in standard control cabinet environments.

Q: What is the primary function of the third pin in the connector assembly? A: The 3-pin layout assigns dedicated paths for positive and negative DC voltage feeds alongside a specific low-impedance chassis grounding route. This grounding path ensures continuous fault-current draining back to the primary enclosure panel earth grid.

Field Installation Guidelines

  • Connector Alignment and Insertion: Align the internal keyways of the 3-pin female connector with the matching male pins on the FPM or baseplate receptacle. Press linearly into position until the mechanical locking mechanism clicks completely into engagement.
  • Bend Radius Constraints: Maintain a permanent physical bend radius of at least 50 mm along the 60-inch cable run. Do not force sharp 90-degree creases near the strain-relief boots to avoid internal wire stress or fatigue fractures.
  • Separation of Conductors: Route the power cable through designated low-voltage DC cabinet pathways. Separate this cable from high-voltage AC motor lines and high-current inductive switching devices by a minimum clearance of 30 cm to suppress external electromagnetic noise pickup.
  • Grounding Continuity: Verify that the mating baseplate chassis possesses a direct low-impedance ground track to the master panel earth bus. This preserves the overall system shielding capabilities mapped through the cable assembly.

Foxboro P0926KN I/A Series Datasheet & Technical Manual

Item no : 17064627686
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 18 - Jul 23

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches