Wilkins 112-375XLFT | 1 1/2" Reduced Pressure Principle Backflow PreventerNOTICE: Product images may vary from the actual item due to differences in size or configuration options. The Wilkins 112 375XLFT is a reduced pressure principle backflow preventer assembly designed to protect potable water supplies from contamination, featuring integral male 45 flare SAE test fittings for reliable cross connection control. Key Specifications: Size: 1 1 2 Inches Maximum Working Pressure: 175 psi Maximum Working Temperature: 180F
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

NOTICE: Product images may vary from the actual item due to differences in size or configuration options.

The Wilkins 112-375XLFT is a reduced pressure principle backflow preventer assembly designed to protect potable water supplies from contamination, featuring integral male 45° flare SAE test fittings for reliable cross-connection control.

 

Key Specifications:

  • Size: 1 1/2 Inches
  • Maximum Working Pressure: 175 psi
  • Maximum Working Temperature: 180°F
  • Notable Certifications: ASSE 1013, cUPC, CSA B64.4
  • End Connections: FNPT Threads

 

Other Related Variants:

  • 12-375XLFT: 1/2 Inch model size
  • 34-375XLFT: 3/4 Inch model size
  • 1-375XLFT: 1 Inch model size
  • 2-375XLFT: 2 Inch model size

 

Materials:

  • Housing: Reinforced Nylon (FDA approved)
  • Fasteners: Stainless Steel, 300 Series
  • Springs: Stainless Steel, 300 Series
  • Ball Valves: Low Lead Cast Bronze, ASTM B 584
  • Elastomers: Silicone (FDA Approved)
  • Elastomers: Buna Nitrile (FDA Approved)
  • Internals: Delrin
  • Internals: Nylon
  • Struts: Stainless Steel, 300 Series

 

Typical Installation:

Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. For indoor installations, an air gap adapter is required.

 

Standards Compliance:

ASSE 1013; cUPC; CSA B64.4; AWWA C511; USC Foundation Approved; NSF/ANSI/CAN 61 & 372

 

Features & Benefits:

  • Lead-Free Protection: NSF/ANSI/CAN 372 certified with less than 0.25% weighted average lead content, ideal for potable water applications requiring lead-free compliance.
  • Dual Protection: Protects against both backsiphonage and backpressure of contaminated water where potential health hazards exist in potable water systems.
  • Durable Construction: Reinforced nylon housing with stainless steel fasteners and FDA-approved elastomers ensures long-lasting performance in demanding conditions.
  • Convenient Testing: Integral male 45° flare SAE test fitting allows easy field testing and maintenance verification of backflow prevention performance.

 

FAQ

 

Q: What is the required installation height for the Zurn 112-375XLFT?

A: The Wilkins 112-375XLFT must be installed at a minimum of 12 inches and a maximum of 30 inches above adequate floor drains with sufficient side clearance for testing and maintenance.

Q: Can this backflow preventer be installed outdoors?

A: Yes, the Zurn 112-375XLFT can be installed outdoors with a protective enclosure. Indoor installations require an air gap adapter. The unit must not be submerged in any installation.

Q: What certifications does this backflow preventer have?

A: This unit is ASSE Listed 1013, cUPC Listed, CSA Certified B64.4, AWWA compliant C511, USC Foundation approved, and meets NSF/ANSI/CAN 61 and 372 requirements for lead-free applications.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

Wilkins 112-375XLFT | 1 1/2" Reduced Pressure Principle Backflow Preventer

Item no : 26397200967
sold recently : Login >>
US$ 864.00
Pay in 4 interest-free payments of $216.00 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 28 - Aug 2

Enjoy 20% off shipping

US$ 864.00

1-11

US$ 777.60

12-35

US$ 604.80

36-59

US$ 518.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches