Shopping security
The Honeywell FC-SDI-1624 (also referenced as SDI-1624) is a high-density Safe Digital Input (SDI) module engineered for integration with Honeywell Safety Manager and Fail Safe Control (FSC) systems. Designed for safety-critical applications, it monitors digital field signals with the highest integrity and reliability. The module is fully certified for SIL 3 applications, ensuring that emergency shutdown (ESD), fire and gas (F&G), and burner management systems (BMS) operate safely under all conditions.
Safety and Diagnostics
SIL 3 Certified: Suitable for high-integrity safety loops.
Continuous Self-Testing: Performs internal diagnostics every few milliseconds to detect faults in hardware or signal lines.
Short-Circuit Detection: Each input channel is protected against shorts to ground or external power sources.
Field Signal Monitoring
Open and Short Circuit Detection: Configurable with end-of-line resistors for monitoring sensor wiring integrity.
Galvanic Isolation: Electrical isolation separates field inputs from internal system logic, preventing surge or noise damage.
Operational Reliability
Low Power Consumption: Optimized to reduce heat and minimize cooling requirements in control cabinets.
Hot-Swap Support: Allows replacement in redundant configurations without interrupting the safety process.
Status Indicators: Front-panel LEDs for each channel show input state and module health at a glance.
| Feature | Specification |
|---|---|
| Model Number | FC-SDI-1624 / SDI-1624 |
| Number of Channels | 16 (isolated in groups) |
| Nominal Input Voltage | 24 VDC |
| Input Current | Approx. 7 mA per channel |
| Maximum Input Voltage | 36 VDC |
| Input Logic Levels | HIGH >15 VDC, LOW <9 VDC |
| Safety Level | SIL 3 |
| Power Dissipation | 1.5–2.0 W depending on load |
| Operating Temperature | -5°C to +70°C (+23°F to +158°F) |
| Weight | Approx. 0.5 kg |
| Module Dimensions | 4 TE width, 3 HE height (4HP, 3U) |
| Approvals | CE, TUV, UL, CSA, FM |
Emergency Shutdown (ESD): Monitoring critical trip and safety signals.
Fire & Gas Systems (F&G): Interfaces with flame, smoke, and gas detectors.
Burner Management Systems (BMS): Verifies valve positions and flame detection.
Critical Process Interlocks: Ensures safe operating conditions before process sequences continue.
Q: Can the FC-SDI-1624 detect wiring faults?
A: Yes, it monitors open circuits and short circuits when used with appropriate EOL resistors.
Q: Is this module hot-swappable?
A: Yes, in redundant configurations it can be replaced without interrupting the safety system.
Q: What safety certification does this module have?
A: It is certified to SIL 3 according to IEC 61508 standards.
Comparison to Similar Models
FC-SDI-1608: Supports fewer channels (8), suitable for smaller I/O racks.
FC-SDI-1632: Higher channel density (32 channels) for larger process control systems.
Ships within 48 hours · Estimated delivery Jul 21 - Jul 26
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order