Wilkins 1-975XL3S | RP Backflow Preventer with Strainer, 1 InchesThe Wilkins 1 975XL3S is a 1 Inch reduced pressure principle backflow prevention assembly with integrated lead free wye type strainer, designed to protect potable water supplies from contamination hazards. Key Specifications: Size: 1 Inches Maximum Working Water Pressure: 25 175 PSI Maximum Working Water Temperature: 180F (82C) Notable Certifications: ASSE 1013, cUPC, CSA B64. 4 End Connections: Female NPT Threaded Other Related Variants: 112 975XL3S:
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

The Wilkins 1-975XL3S is a 1 Inch reduced pressure principle backflow prevention assembly with integrated lead-free wye type strainer, designed to protect potable water supplies from contamination hazards.

 

Key Specifications:

  • Size: 1 Inches
  • Maximum Working Water Pressure: 25/175 PSI
  • Maximum Working Water Temperature: 180°F (82°C)
  • Notable Certifications: ASSE 1013, cUPC, CSA B64.4
  • End Connections: Female NPT Threaded

 

Other Related Variants:

  • 112-975XL3S: 1 1/2 Inches version
  • 114-975XL3S: 1 1/4 Inches version
  • 12-975XL3S: 1/2 Inches version
  • 2-975XL3S: 2 Inches version
  • 34-975XL3S: 3/4 Inches version

 

Materials:

  • Main Valve Body and Access Covers: Low Lead Cast Bronze ASTM B584
  • Fasteners: Stainless Steel, 300 Series
  • Elastomers: Silicone (FDA Approved) and Buna Nitrile (FDA Approved)
  • Polymers: Noryl™
  • Springs: Stainless Steel, 300 Series
  • Ball Valve Handles: Stainless Steel

 

Typical Installation:

Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches (305mm) and a maximum of 30 inches (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.

 

Standards Compliance:

ASSE Listed 1013; cUPC Listed; CSA Certified B64.4; UL Classified; C-UL Classified; AWWA Compliant C511; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; NSF/ANSI/CAN 61 and 372

 

Features & Benefits:

  • Health Hazard Protection: Provides comprehensive protection against both backsiphonage and backpressure of contaminated water into potable water supply systems.
  • Lead-Free Construction: Meets NSF/ANSI/CAN 372 with less than 0.25% weighted average lead content, ensuring safe drinking water compliance for health-conscious applications.
  • Easy Maintenance Access: First and second checks are accessible for maintenance without removing the relief valve or the entire device from the line, reducing downtime and service costs.
  • Complete System Ready: Supplied with full port QT ball valves, integral test fittings, and optional Model SXL lead-free wye type strainer for comprehensive installation convenience.

 

FAQ

 

Q: What is the proper installation height for the Wilkins 1-975XL3S backflow preventer?

A: The Zurn 1-975XL3S assembly must be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The unit must never be submerged.

Q: Can the Wilkins 1-975XL3S be used with hot water systems?

A: Yes, the 1-975XL3S is rated for a maximum working water temperature of 180°F (82°C), with a minimum temperature of 33°F, making it suitable for a wide range of hot and cold water applications.

Q: What pressure reducing valves pair well with the Zurn 1-975XL3S for a complete system?

A: The recommended PRV pairings include Model 500XL3, Model 600XL3, and Model 625XL3 Pressure Reducing Valves for optimal system performance and compatibility.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

Wilkins 1-975XL3S | RP Backflow Preventer with Strainer, 1 Inches

Item no : 2790361495
sold recently : Login >>
US$ 560.00
Pay in 4 interest-free payments of $140.00 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 6 - Aug 11

Enjoy 20% off shipping

US$ 560.00

1-11

US$ 504.00

12-35

US$ 392.00

36-59

US$ 336.00

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches