2711P-RDT10C Allen-Bradley PanelView Plus 1000 Datasheet & Technical ManualAllen Bradley 2711P RDT10C PanelView Plus 1000 Display Module The Allen Bradley 2711P RDT10C serves as the primary 2711P RDT10C Display Module utilized to execute [Specific Technical Task] across PanelView Plus 1000 platforms. Hardware Specifications Parameter Specification Model 2711P RDT10C Brand Allen Bradley Origin USA Weight 4. 00 lbs (1. 81 kg) Dimensions 12. 48 x 10. 47 x 4. 57 in (317 x 266 x 116 mm) Operating Temp 0 to 55 deg C Power
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Allen-Bradley 2711P-RDT10C PanelView Plus 1000 Display Module

The Allen-Bradley 2711P-RDT10C serves as the primary 2711P-RDT10C Display Module utilized to execute [Specific Technical Task] across PanelView Plus 1000 platforms.

Hardware Specifications

Parameter Specification
Model 2711P-RDT10C
Brand Allen-Bradley
Origin USA
Weight 4.00 lbs (1.81 kg)
Dimensions 12.48 x 10.47 x 4.57 in (317 x 266 x 116 mm)
Operating Temp 0 to 55 deg C
Power Consumption Powered via host terminal logic module base
Operator Input Option Analog resistive touchscreen
Graphics Type Color TFT LCD
Display Size 10.4 Inches
Resolution 640 x 480 pixels (VGA)
Color Support 18-bit (262,144 colors)
Backlight Type Replaceable CCFL (50,000 hours typical half-life)
Operating Shock 15 g peak for 11 ms
Non-Operating Shock 30 g peak for 11 ms
Operating Altitude Up to 2000 m above sea level
Relative Humidity 5% to 95% non-condensing
Enclosure Type Rating NEMA Type 12, 13, 4X indoor use only

Industrial Control & Drive Integration

The 2711P-RDT10C manages real-time visualization matrices synchronized directly with the backplane bus communication velocity properties of the host PanelView assembly. Real-time register graphics scale dynamically based on I/O density scaling routines executed within connected control logic modules. To prevent communication latency or display flickering when rendering high-density operational data fields across Profinet / EtherNet/IP deterministic networks, strict firmware flash compatibility must be validated between this interface hardware and the corresponding logic processing unit.

Frequently Asked Questions

Q: Can the 2711P-RDT10C operate as an independent standalone Human Machine Interface (HMI)?

A: No. The 2711P-RDT10C is a dedicated display sub-assembly module containing only the physical LCD panel, backlight, and resistive touch matrix. It requires mechanical coupling and electrical mating with a compatible PanelView Plus 1000 logic module to establish processing and communication capabilities.

Q: What mitigation actions must be taken if the backlight goes out or drops below functional luminosity limits?

A: The display contains a replaceable cold-cathode fluorescent lamp (CCFL) backlight component. When operational hours approach the 50,000-hour threshold, the backlight assembly can be extracted and replaced from the rear of the unpowered module housing without replacing the entire liquid crystal display grid.

Field Installation Guidelines

  • Mechanical Panel Cutout Alignment: Prepare the enclosure panel cutout to match the specified dimensions of the 1746/1747 Bulletin scale footprint. Guide the module into the panel opening, making sure the integrated perimeter sealing gasket sits flush against the exterior panel plate to maintain NEMA Type 4X indoor protection levels.
  • Securing Torque Layout: Install the provided mounting clips into the slots around the perimeter of the display module. Tighten the mounting screws in an alternating sequence to the specified torque limit to prevent faceplate warping or cracking of the analog resistive touchscreen layer.
  • Electrical Ground Integrity: Ensure the host logic chassis is grounded via a low-impedance conductor back to the main enclosure structural ground bus. A clean reference ground connection is required to eliminate high-frequency electrical noise that could introduce coordinate drift or false touch registrations into the analog resistive touch matrix.

2711P-RDT10C Allen-Bradley PanelView Plus 1000 Datasheet & Technical Manual

Item no : 28398859153
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 22 - Jul 27

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches