20% OFF shipping at terrelite.it on orders over $79 + up to 10% OFF products
terrelite.it
home > FC-TDIO51 Honeywell Experion PKS Mixed I/O Card | SIL 2 Rated > FC-TDIO51 Honeywell Experion PKS Mixed I/O Card | SIL 2 Rated
download picture
FC-TDIO51 Honeywell Experion PKS Mixed I/O Card | SIL 2 RatedProduct Overview The Honeywell FC TDIO51 serves as a high performance Mixed Digital Input Output module within the Experion PKS and C Series I O subsystem. This dual functionality module integrates 8 digital inputs and 8 digital outputs into a single, compact unit, significantly optimizing cabinet space. It interfaces directly with field devices such as switches, sensors, and solenoids to provide real time monitoring and actuation. We offer this
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Overview

The Honeywell FC-TDIO51 serves as a high-performance Mixed Digital Input/Output module within the Experion PKS and C-Series I/O subsystem. This dual-functionality module integrates 8 digital inputs and 8 digital outputs into a single, compact unit, significantly optimizing cabinet space. It interfaces directly with field devices such as switches, sensors, and solenoids to provide real-time monitoring and actuation. We offer this module as 100% Brand New and Original, ensuring full compliance with safety-critical automation standards and peak system reliability.

Technical Specifications

Attribute Specification Value
Model Number FC-TDIO51
Channel Count 16 Total (8 Digital Inputs / 8 Digital Outputs)
Input Specification 24 VDC (Configurable PNP/NPN)
Output Type Relay (Changeover)
Switching Capacity 5 A per channel (250 VAC / 30 VDC)
Safety Rating SIL 2 (IEC 61508 Compliant)
Isolation Rating 2.5 kV AC (Channel to Backplane)
Response Time Input ≤ 2 ms; Output ≤ 5 ms
Power Consumption 12 W Maximum
Operating Temperature –20°C to +60°C
Dimensions 130 × 90 × 70 mm

Engineering Advantages

  • Space-Efficient Hybrid Design: The FC-TDIO51 combines monitoring and control tasks in one module. This hybrid architecture reduces the total number of modules required in a rack, lowering hardware costs and minimizing the physical footprint of control cabinets.

  • SIL 2 Safety Integration: This module carries SIL 2 certification, meeting rigorous IEC 61508 standards. It provides the diagnostic coverage and fail-safe performance necessary for safety-instrumented systems (SIS) in hazardous environments like petrochemical plants.

  • Superior Signal Integrity: A 2.5 kV AC isolation rating protects the internal system backplane from field-side electrical surges and ground loops. This robust barrier prevents noise interference from compromising the accuracy of the control processor.

  • High-Current Switching: The integrated relay outputs support up to 5 A resistive loads. This allows the module to drive heavy-duty solenoids and motor starters directly, often eliminating the need for intermediate interposing relays.

  • Rapid Fault Response: With millisecond-level switching speeds (Input ≤ 2 ms), the FC-TDIO51 captures transient process events and executes safety interlocks with virtually zero latency, protecting downstream mechanical equipment from damage.

FAQs

  • Can I configure the inputs for both NPN and PNP sensors?

    Yes. The FC-TDIO51 supports configurable 24 VDC digital inputs, allowing seamless integration with a wide variety of industrial proximity sensors and switches regardless of their polarity.

  • Is the FC-TDIO51 compatible with the Honeywell Safety Manager?

    Absolutely. While it integrates natively with Experion PKS, its SIL 2 rating and high isolation make it a standard choice for Honeywell Safety Manager systems in process industries.

  • What mounting requirements does this module have?

    The module requires installation within an IP20-rated cabinet. It utilizes the standard C-Series/Experion I/O backplane for power and communication, ensuring a secure, vibration-resistant fit.

  • How do the relay outputs behave during a power loss?

    The changeover relay outputs provide mechanical switching. Depending on your wiring (Normally Open or Normally Closed), the module ensures a predictable physical state for field devices during system de-energization.

FC-TDIO51 Honeywell Experion PKS Mixed I/O Card | SIL 2 Rated

Item no : 35543682652
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 12 - Jul 17

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches