Shopping security
The Honeywell 10018/E/1 is a high-density, 64-channel digital input module engineered for Fail-Safe Control (FSC) systems. Designed for Safety Instrumented Systems (SIS), Emergency Shutdown (ESD), and Fire & Gas (F&G) monitoring, this module ensures reliable and fault-tolerant operation in critical industrial environments. Its Non-Interfering (NI) design isolates each channel, preventing a single fault from impacting the entire rack. The “E” designation indicates a conformal-coated version, offering enhanced protection against moisture, dust, and corrosive contaminants.
64 isolated digital input channels to maximize rack efficiency
Galvanic isolation via opto-couplers between field wiring and internal system logic
Conformal coating compliant with ISA S71.04 Class G3 for harsh conditions
Continuous self-diagnostics to detect stuck-at or wiring faults
Hot-swappable design for minimal system downtime
Electrical Characteristics
Input Type: Current-sinking digital input
Nominal Voltage: 24 VDC
Maximum Voltage: 30 VDC
Typical Input Current: 5 mA per channel
Logic Thresholds: ON ≥ 15 VDC, OFF ≤ 5 VDC
Input Response Time: 10 ms typical
Isolation & Safety
Channel-to-channel isolation: internal Non-Interfering (NI) design
Field-to-logic isolation: 2500 VDC
Supports redundant configurations for dual or triple modular redundancy
Environmental Ratings
Operating Temperature: 0°C to 60°C
Storage Temperature: -25°C to 85°C
Relative Humidity: 5% to 95% non-condensing
Vibration and shock: Industrial cabinet rated
Physical Characteristics
Dimensions: 126 × 70 × 30 mm
Weight: 0.91 kg (approx. 2 lbs)
Power Dissipation: ~3.5 W at full load
Status Indicators: Optional LED per channel
Emergency Shutdown systems monitoring critical field signals
Fire & Gas systems including flame and smoke detectors
Burner Management Systems (BMS) for fuel valves and flame sensing
Process Safety monitoring for high-pressure or high-temperature trips
Q: Can the module be replaced without shutting down the system?
A: Yes, the 10018/E/1 supports hot-swapping for minimal disruption.
Q: Is this module compatible with redundant FSC configurations?
A: Yes, it can operate in dual or triple modular redundancy setups with FSC software.
Q: Does the conformal coating provide protection against corrosive chemicals?
A: Yes, the “E” version is ISA S71.04 Class G3 compliant.
Q: What types of field devices can be connected?
A: Compatible with push buttons, limit switches, pressure switches, and other standard digital sensors.
Ships within 48 hours · Estimated delivery Jul 28 - Aug 2
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order