Shopping security
The Electrocorder EC-2VA is a single-phase voltage, current, power and energy logger for load studies, voltage/current investigations and energy monitoring where flexible current sensing is useful.
Use it when you need to understand how a single-phase circuit or item of equipment behaves over time, including whether low voltage is linked to high current demand. The EC-2VA combines a voltage connection with a flexible Rogowski current sensor, making it useful where conductors are larger or where a split flexible coil is easier to fit.
Best for:
Consider another model if:
What you get:
Set up the logger in Electrosoft, connect the voltage lead and fit the Rogowski coil around the conductor being monitored, then start recording. When enough data has been captured, connect the logger to a PC by USB and use Electrosoft to view, save, export and report on the results.
Typical applications: The EC-2VA is intended for single-phase power and energy investigations where voltage and current need to be understood together.
What the EC-2VA records:
Why constant sampling matters: many instruments only take periodic snapshots. The Electrocorder continuously samples throughout the averaging period, helping capture short events, changing loads and trend data that can otherwise be missed.
Recording duration depends on the selected averaging period. Longer periods support energy-use monitoring, while shorter periods can be used for more detailed investigations.
The logger is typically fitted by a competent person at a distribution board, meter board or suitable test point. The Rogowski coil opens at the joint so it can be placed around a conductor without breaking the main circuit.
Related application guides:
These related Electrocorder case studies, application pages and articles show how this type of logging is used in practical investigations.
Energy Auditing
A knowledge page explaining how recorded electrical data supports energy audits, load profiling and evidence-based recommendations.
Performing an Energy Audit
An article covering practical energy-audit steps and the value of recorded electrical usage data.
Voltage Optimisation
A knowledge page explaining why measured voltage and load data can support optimisation decisions.
High consumer voltage is now the BIG problem
An article discussing high voltage problems and the need for recorded evidence.
Documentation:
Download the EC-2VA datasheet and user instructions for detailed technical information, installation guidance and operating instructions.
| Datasheet | |
| User Instructions (English) |
Free Electrosoft PC software
Electrosoft is compatible with Windows 11 down to Windows 7. It lets you view and zoom current, power and energy graphs, export data to Microsoft Excel, email results to colleagues, and print or save reports as PDF files with your company logo.
Electrosoft includes statistics, load balancing, tariff and costing analysis, annual CO2 and energy usage projections, logger management and calibration management tools. Sample files are included so you can try the software without having a logger connected.
| Download Electrosoft PC software |
When to choose the EC-2VA
Choose this model when the investigation needs single-phase voltage, current, power and energy data and a flexible current sensor is useful.
Compare with related Electrocorder models
If a clamp-on CT is a better physical fit, consider the CT-2VA. If the load plugs into a standard socket, consider the AL-2VA. For three-phase systems, consider the EC-7VAR-RS.
Key features:
Measurement note
Because the EC-2VA measures voltage and current together, it can support power and energy analysis. It should be installed by a competent person where access to conductors or distribution equipment is required.
Included with your single-phase power and energy logger with flexible Rogowski coil:
Shipping and origin details:
Determining product order codes:
To specify your Electrocorder select various codes and enter into the boxes in order to create an accurate product code. For example: EC-2VA-5H-UK-IP65-SET.

What is the EC-2VA used for?
It is used for single-phase voltage, current, power and energy monitoring.
Why choose a Rogowski coil?
A Rogowski coil is flexible and can be easier to fit around larger conductors or awkward cable arrangements.
How is it different from CT-2VA?
The EC-2VA uses a flexible Rogowski coil. The CT-2VA uses a clamp-on current transformer.
Can it show whether low voltage is linked to high current demand?
Yes. Because it records voltage and current together, it can help compare voltage behaviour with load demand.
What software is used to analyse the data?
Electrosoft PC software is used to configure the logger, download recorded data, view graphs, export data and create reports.
Ships within 48 hours · Estimated delivery Jul 24 - Jul 29
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order