20% OFF shipping at terrelite.it on orders over $79 + up to 10% OFF products
terrelite.it
home > S2BN1D-11130 Yokogawa N-IO Base Plate Module | New & Original Stock > S2BN1D-11130 Yokogawa N-IO Base Plate Module | New & Original Stock
download picture
S2BN1D-11130 Yokogawa N-IO Base Plate Module | New & Original StockYokogawa S2BN1D 11130 ProSafe RS N IO Base Plate The Yokogawa S2BN1D 11130, also cataloged as the S2BN1D Base Plate with Disconnecting Terminal, operates as a dedicated hardware component for field device connection management within ProSafe RS N IO platforms. Suffix Breakdown & Model Matrix Suffix Code Functional Description 1 Wall mount installation profile 1 Pressure clamp terminal block mechanism for field wiring connections 1 Explosion protection
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Yokogawa S2BN1D-11130 ProSafe-RS N-IO Base Plate

The Yokogawa S2BN1D-11130, also cataloged as the S2BN1D Base Plate with Disconnecting Terminal, operates as a dedicated hardware component for field device connection management within ProSafe-RS N-IO platforms.

Suffix Breakdown & Model Matrix

Suffix Code Functional Description
-1 Wall mount installation profile
1 Pressure clamp terminal block mechanism for field wiring connections
1 Explosion protection architecture
3 Conformal coating matching ISA Standard G3 specifications with a wide operational temperature configuration
0 Fixed production design digit

Hardware Specifications

Parameter Specification
Model S2BN1D-11130
Brand Yokogawa
Origin Japan
Weight 1.4 kg
Dimensions Standard N-IO base plate chassis orientation footprint
Operating Temp -55 to +85 deg C (Suffix 3 standard performance range covers -40 to +70 deg C)
Power Consumption System link via S2KPB10 power cable; Field Power Supply Rating: 24 V DC (+20% / -10%), up to 11.0 A
Channel Capacity 16 channels supporting single or redundant I/O configurations
Over Voltage Protection Active detection level less than or equal to 32 V
Dielectric Withstanding Voltage 1500 V AC for 1 minute between I/O and system; continuous 42 V DC rating
Backplane Contact Resistance Inner contact parameters rated at 2 mOhm
Environmental Enclosure Rating IEC 60529:2001, IP66 status
Mechanical Resistance Compliance MIL-STD-1344A (Corrosion), MIL-STD-202F (Vibration)
Software Environment Framework Supported on software version R4.01 or later

Process Control & DCS Instrumentation Properties

The Yokogawa S2BN1D-11130 establishes 16 isolated physical channels optimized to run 4-20 mA HART loop protocol passes directly into the N-IO control sub-layer. The hardware traces contain distinct channel-to-channel isolation layouts to block common-mode voltage fluctuations, grounding noise, and dangerous transient overshoots from entering the primary F-SB bus network. When combined with conformal coating matching ISA Standard G3 severity limits, the base plate operates inside aggressive atmospheres while running real-time loop feedback verification and active over-voltage protection cutting off lines spiking above 32 V.

Frequently Asked Questions

Q: How does the integrated 32 V over-voltage protection circuit respond when external field power rails spike unpredictably?

A: The onboard hardware monitors the input power feeds continuously. Whenever incoming loops cross the safety threshold and spike above 32 V, the protection circuit cuts the link to safeguard the underlying N-IO modules from over-voltage degradation.

Q: Can the base plate be serviced or have field cables manipulated while the main node continues to execute active safety loops?

A: The base plate uses disconnecting terminal blocks to isolate field wiring loops during maintenance routines. Technicians can open individual terminal segments to check or service a single field channel without shutting down the entire 16-channel row.

Q: What grounding steps must be followed to keep the 1500 V AC dielectric withstanding voltage threshold intact?

A: Connect a heavy copper drain conductor directly to the dedicated M3 screw terminal on the chassis frame. This dedicated pathway routes electromagnetic noise and high-voltage surges straight to the master instrumentation earth, preventing noise from crossing between channels.

Field Installation Guidelines

  • Chassis Mechanical Mounting: Secure the assembly firmly inside the control enclosure using the wall mount holes with M4 x 4 screws, or lock it directly onto a standard DIN rail profile. Maintain vertical orientation to allow unrestricted convection cooling across adjacent components.
  • Pressure Clamp Conductor Termination: Insert stripped wire ends directly into the suffix-designated pressure clamp blocks. Ensure the spring mechanism grips the raw copper conductor tightly to prevent high-resistance connection points in high-vibration applications.
  • Power Supply Cable Engagement: Route the main system voltage line through a dedicated S2KPB10 base plate power supply cable assembly. Secure the locking clips completely to keep the 11.0 A continuous power rail stable under heavy load conditions.
  • Field Signal Cable Segregation: Route all low-voltage analog inputs and F-SB bus cables away from high-voltage AC lines and motor starter circuits. Use dedicated, grounded metal wire tracks inside the cabinet layout to eliminate electromagnetic cross-talk.

S2BN1D-11130 Yokogawa N-IO Base Plate Module | New & Original Stock

Item no : 46331822087
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 21 - Jul 26

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches