The Honeywell TC-IXL061 functions as a high-precision, low-level analog input interface for the Experion PKS Series C I/O family. This 100% Brand New and Original module specifically targets critical temperature-sensing applications by directly accepting millivolt (mV) signals from a diverse range of thermocouple types. It utilizes an advanced 16-bit Delta-Sigma analog-to-digital converter (ADC) to provide the high-resolution thermal data necessary for tight regulation in mission-critical process loops. Its vertically-mounted Series C architecture optimizes heat dissipation and maximizes cabinet space efficiency in centralized control environments.
| Parameter | Specification Details |
| Manufacturer | Honeywell International Inc. |
| Model Number | TC-IXL061 |
| Hardware Series | Experion PKS Series C |
| Module Type | Low-Level Analog Input (TC/mV) |
| Input Channels | 16 Channels (IOTA dependent) |
| A/D Conversion | 16-bit Delta-Sigma ADC |
| Supported T/C Types | J, K, T, E, R, S, B, N |
| Cold Junction Compensation | Via external IOTA with CJR sensor |
| Isolation | Galvanic (Field-to-System Logic) |
| Operating Temp | 0 to 60 deg C |
| Dimensions | 7 cm x 14 cm x 14.5 cm |
| Weight | 0.5 kg (1.1 lbs) |
High-Resolution Thermal Data: The 16-bit Delta-Sigma ADC architecture eliminates signal noise and provides ultra-fine granularity. This precision allows the C300 controller to maintain stable setpoints in sensitive thermal processes, such as chemical reactors and high-pressure steam headers.
Aggressive Noise Rejection: Honeywell engineers this module to filter out electromagnetic interference (EMI) typical of industrial environments. By utilizing sophisticated hardware filtering and galvanic isolation, the TC-IXL061 prevents field-side transients and ground loops from corrupting the low-voltage thermocouple signals.
Simplified Thermal Management: The Series C vertical mounting design facilitates natural convection. This prevents localized hotspots within the I/O rack, extending the life of the internal electronics and ensuring measurement stability across the entire 0 to 60 deg C operating range.
Deterministic Signal Updates: The module publishes process data to the I/O Link at a deterministic rate. This ensures that the control strategy receives fresh temperature data without variable jitter, supporting the high-speed execution requirements of the Experion PKS architecture.
How does the TC-IXL061 handle Cold Junction Compensation (CJC)?
The module relies on Cold Junction Reference (CJR) sensors located on the associated I/O Termination Assembly (IOTA). This ensures the most accurate temperature compensation by measuring the actual terminal temperature where the thermocouple wires connect.
Can I mix different thermocouple types on a single TC-IXL061?
Yes. You configure each channel independently via the Experion PKS Configuration Studio. This flexibility allows one module to monitor a variety of sensors, such as Type K for high-temp exhaust and Type T for lower-temp process fluids.
Is this module compatible with standard millivolt (mV) inputs?
While primarily used for thermocouples, the TC-IXL061 functions as a high-precision low-level analog input unit. It accurately interprets direct millivolt signals within its rated input range, making it suitable for other low-voltage specialty sensors.
What mounting assembly is required for installation?
The TC-IXL061 requires a specific Series C IOTA. Ensure you select the correct 6-inch or 12-inch IOTA that supports the 16-channel thermocouple configuration and includes the necessary CJR sensors.