Electrocorder LS-1V Interruption Voltage LoggerOverview The Electrocorder LS 1V is a single phase voltage interruption logger for recording when supply voltage is present or absent over time. Use it when the key question is not detailed voltage variation, but when the supply is on or off. The LS 1V records the dates and times when voltage is above or below a user defined threshold, making it useful for power interruption studies and equipment on off cycle monitoring. Best for: Long term power
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols
Overview

The Electrocorder LS-1V is a single-phase voltage interruption logger for recording when supply voltage is present or absent over time.

Use it when the key question is not detailed voltage variation, but when the supply is on or off. The LS-1V records the dates and times when voltage is above or below a user-defined threshold, making it useful for power interruption studies and equipment on/off cycle monitoring.

Best for:

  • Long-term power supply interruption monitoring.
  • Recording periods when grid voltage is present or absent.
  • Monitoring equipment duty cycles, such as compressor or motor on/off periods.
  • Checking intermittent supply availability in remote or unreliable supply areas.
  • Simple event-style voltage presence logging.

Consider another model if:

  • You need detailed voltage levels, dips and swells, where the EC-1V or EC-2V may be more appropriate.
  • You need voltage and current together, where the EC-2VA, CT-2VA or EC-7VAR-RS may be a better fit.
  • You need three-phase voltage monitoring, where the EC-3V or SL-3V may be more appropriate.

What you get:

  • LS-1V logger.
  • Voltage lead, USB lead, carry case, batteries, user instructions and free Electrosoft analysis software.
  • A voltage interruption logger for recording on/off periods against a user-defined threshold.

Set up the logger in Electrosoft, plug it into the monitored supply, then start recording. When enough data has been captured, disconnect the logger, connect it to a PC by USB and use Electrosoft to view, save, export and report on the results.

Applications

Typical applications: The LS-1V is intended for voltage presence and interruption studies rather than detailed voltage quality analysis.

What the LS-1V records:

  • Dates and times when voltage is above the configured threshold.
  • Dates and times when voltage is below the configured threshold.
  • Power supply interruption periods.
  • Equipment voltage on/off cycles where voltage presence indicates operation.

Why constant sampling matters: many instruments only take periodic snapshots. The Electrocorder continuously samples throughout the averaging period, helping capture short events, changing loads and trend data that can otherwise be missed.

Recording duration depends on the configuration and the interruption study being carried out. It is intended for long-term evidence of supply availability or equipment cycling.

When fitted with the appropriate plug or voltage lead arrangement, the LS-1V can be used as a simple plug-in interruption logger.

Case Studies

These related Electrocorder case studies, application pages and articles show how this type of logging is used in practical investigations.

Cycling of Closed Loop Control Systems
A knowledge page about using recorded data to understand cycling behaviour in controlled systems.

Machines or Equipment Resetting
An article about using recorded electrical evidence to investigate resets and intermittent operating problems.

Some Electrocorder Recording Facts
An article explaining practical facts about Electrocorder recording and how the data is captured.

Resources

Documentation:
Download the LS-1V datasheet and user instructions for detailed technical information, installation guidance and operating instructions.

Single Phase Voltage Interruption Logger Datasheet Datasheet
Single Phase Voltage Interruption Logger User Instructions User Instructions (English)

Free Electrosoft PC software
Electrosoft is compatible with Windows 11 down to Windows 7. It lets you view and zoom current, power and energy graphs, export data to Microsoft Excel, email results to colleagues, and print or save reports as PDF files with your company logo.

Electrosoft includes statistics, load balancing, tariff and costing analysis, annual CO2 and energy usage projections, logger management and calibration management tools. Sample files are included so you can try the software without having a logger connected.

Electrosoft software icon Download Electrosoft PC software
Features

When to choose the LS-1V
Choose this model when the investigation is about supply presence, supply interruption or equipment on/off timing rather than detailed voltage level analysis.

Compare with related Electrocorder models
If you need detailed voltage level data, consider EC-1V or EC-2V. If voltage and current together are needed, consider EC-2VA, CT-2VA or EC-7VAR-RS.

Key features:

  • Records voltage on/off periods against a user-defined threshold.
  • Useful for supply interruption studies and equipment duty-cycle checks.
  • Simple plug-in style use where the correct voltage lead or plug is supplied.
  • Data includes dates and times of voltage presence and absence.
  • Designed for long-term interruption evidence rather than full power analysis.

Measurement note
The LS-1V is an interruption logger. It is not intended to replace a full voltage quality recorder when detailed voltage level, dip or swell data is required.

Included with your single-phase voltage interruption logger:

  • LS-1V logger.
  • Voltage lead, USB lead, carry case, batteries, user instructions and free Electrosoft analysis software.
  • A voltage interruption logger for recording on/off periods against a user-defined threshold.

Determining product order codes:

To specify your Electrocorder select various codes and enter into the boxes in order to create an accurate product code. For example: LS-1V-5H-UK-IP65-SET.

LS-1V product order code diagram

FAQ

What does the LS-1V record?
It records when voltage is above or below a user-defined threshold, with dates and times.

Is it the same as an EC-1V?
No. The EC-1V records voltage levels. The LS-1V is focused on voltage presence and interruption events.

Can it monitor equipment cycling?
Yes. If voltage presence indicates equipment operation, it can record on/off timing.

Can it help with unreliable supply investigations?
Yes. It can record long-term periods when supply voltage is present or absent.

What software is used to analyse the data?
Electrosoft PC software is used to configure the logger, download recorded data, view data and create reports.

Electrocorder LS-1V Interruption Voltage Logger

Item no : 55410418579
sold recently : Login >>
US$ 238.00
Pay in 4 interest-free payments of $59.50 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 23 - Jul 28

Enjoy 20% off shipping

US$ 238.00

1-11

US$ 214.20

12-35

US$ 166.60

36-59

US$ 142.80

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

HL-EL160
HL-EL160

US$ 39.99

Min. order: 1 piece

4.5 (115 reviews)

Sold : Login>>

Related Searches