The Gill MaxiMet GMX300 is an extremely compact, robust and lightweight solution for accurately measuring weather parameters. Three double-louvered naturally aspirated radiation shields deliver long term highly accurate data. Parameters measured include temperature, relative humidity, barometric pressure, absolute humidity, air density and wet bulb temperature.
The result is an extremely durable and cost effective weather station widely used for applications such as agriculture, health & safety, transport, education, energy and building controls.
Richard Paul Russell Ltd. can connect the sensor to the WeatherFile.com website where data can be viewed using any internet connected device and downloaded for detailed analysis in a .CSV file format.

• Building and industrial controls
• Authorities
• Transport
• Coastal
• Agricultural
• Safety
• Educational
• Commercial
• Energy
Temperature, humidity and pressure sensor
• Naturally aspirated
• UV stable radiation shield
• Dust and precipitation protected
• Lightweight and compact
• Robust construction
• Low power consumption
• No moving parts
• Extremely low maintenance
• 24 months warranty
| Temp, Humidity & Pressure | Air Pressure / Temperature | |
| Relative / Absolute humidity | ||
| Naturally aspirated UV stable radiation shield | ||
| Protection against wind-blown precipitation/dust | ||
| Parameters | Temperature °C / °F / °K | |
| Relative humidity & Rh | ||
| Barometric pressure hPa, mbar, mm Hg, In Hg | ||
| Absolute humidity g/m3 | ||
| Air density kg/m3 | ||
| Wet bulb temperature °C / °F / °K | ||
| Angle of Tilt | ||
| Outputs RS232, 422, 485 (ASCII), SDI-12, NMEA, MODBUS, Analogue (option) | ||
| GPS (Manual) | Height above sea level m | |
| Sunrise/sunset | ||
| Position of the sun | ||
| Twilight | ||
| Solar Noon | ||
| MSL pressure | ||
| Temperature | Range | -40°C to +70 °C |
| Resolution | 0.1 | |
| Accuracy | ± 0.3°C @ 20°C | |
| Sampling Rate | 1 Hz | |
| Units | °C, °F, °K | |
| Humidity | Range | 0-100% |
| Resolution | 1% | |
| Accuracy | ± 2% @ 20°C (10%-90% RH) | |
| Sampling Rate | 1 Hz | |
| Units | % Rh, g/m3 | |
| Dew Point | Range | -40°C to +70°C |
| Resolution | 0.1 | |
| Accuracy | ± 0.3°C @ 20°C | |
| Units | °C, °F, °K | |
| Sampling Rate | 1 Hz | |
| Pressure | Range | 300 to 1100 hpa |
| Resolution | 0.1 hPa | |
| Accuracy | ± 0.5 hPa @ 25°C | |
| Sampling Rate | 1 Hz | |
| Units | hPa, mbar, mmHg, inHg | |
| Outputs | Output rate | 1/s, 1/min, 1/hr |
| Digital Comms Modes | Serial RS232, RS422, RS485, SDI-12, NMEA, MODBUS, ASCII | |
| Analogue Outputs | Available via seperate optional device | |
| Power | Power Supply | 5 to 30 Vdc |
| Power (Nominal) 12 Vdc | 5 mA continuous high mode. 0.7 mA eco-power mode (1 hour polled) | |
| Environmental Conditions | IP Rating | 66 |
| Operational Temperature Range | -40°C to +70°C | |
| EMC Standard | BS EN 61326 : 2013 FCC CFR47 parts 15.109 |
|
| CE Marking | Yes | |
| RoHS compilant | Yes | |
| Weight | 0.5 Kg | |
| Origin | UK | |
NOTE: the temperature, humidity and barometer sensors are located internally and are not maintainable or replaceable by a user. Consideration should be given to checking the pressure readings against a standard every 12 months and maintaining the temperature and humidity sensor every 12-24 months. If required you can return the MaxiMet to Richard Paul Russell Ltd to check the barometer calibration, please contact us at [email protected] for more details.