20% OFF shipping at terrelite.it on orders over $79 + up to 10% OFF products
terrelite.it
home > ABB SF810INT-LOS-UV-T-L | SIL-Rated Industrial Flame Monitor > ABB SF810INT-LOS-UV-T-L | SIL-Rated Industrial Flame Monitor
download picture
ABB SF810INT-LOS-UV-T-L | SIL-Rated Industrial Flame MonitorProduct Overview The ABB SF810INT LOS UV T L (Part Number: F810I LOS UV TL) is a high performance ultraviolet flame scanner designed for direct Line of Sight (LOS) mounting. Unlike fiber optic variants, this model mounts directly to the burner front, providing a clear, unobstructed view of the flame zone. It utilizes a solid state Silicon Carbide (SiC) photodiode to detect the specific UV radiation emitted during combustion while remaining blind to
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Overview

The ABB SF810INT-LOS-UV-T-L (Part Number: F810I-LOS-UV-TL) is a high-performance ultraviolet flame scanner designed for direct Line-of-Sight (LOS) mounting. Unlike fiber-optic variants, this model mounts directly to the burner front, providing a clear, unobstructed view of the flame zone. It utilizes a solid-state Silicon Carbide (SiC) photodiode to detect the specific UV radiation emitted during combustion while remaining blind to background infrared from hot refractory surfaces. We supply this unit as 100% Brand New and Original, providing a fail-safe solution for utility boilers, industrial furnaces, and complex multi-burner configurations.

Technical Specifications

Parameter Specification
Model Number SF810INT-LOS-UV-T-L / F810I-LOS-UV-TL
Detection Technology Solid-state SiC Photodiode (UV)
Spectral Peak 280 nm
Installation Type Direct Line-of-Sight (LOS)
Supply Voltage 24 VDC (18–29 VDC)
Power Consumption 3.6 W Typical
Analog Output 4–20 mA (Isolated)
Relay Output Flame Relay (NO Contact, 240 VAC / 1.5 A)
Digital Comms Dual RS-485 (Modbus RTU, Profibus DP-V1)
Housing Material Rugged Stainless Steel
Protection Rating IP66
Temperature Range –40°C to +70°C (Electronics) / Up to 350°C (Tip)

Engineering Advantages

  • Optimized Direct Viewing: The LOS configuration eliminates the signal attenuation associated with fiber-optic cables. This provides the highest possible signal-to-noise ratio, making it the preferred choice for wall-fired and corner-fired boilers where a direct path to the flame exists.

  • SiC Photodiode Precision: The Silicon Carbide sensor ignores visible light and infrared radiation. This prevents "false flame" signals caused by glowing hot furnace walls or molten slag, ensuring the scanner only reacts to active combustion.

  • Fail-Safe Architecture: The device employs a deterministic safety logic that defaults to a "no flame" status upon detecting an internal hardware fault or power loss. This design supports SIL-rated safety instrumented systems for critical burner management.

  • Integrated Communication Suite: Dual RS-485 ports support both Modbus RTU and Profibus DP-V1. This allows for seamless integration into ABB Symphony Plus, 800xA, or third-party DCS environments for real-time monitoring of flame intensity and frequency.

  • Severe Duty Durability: Enclosed in a stainless-steel housing with an IP66 rating, the scanner withstands the vibrations and corrosive atmospheres typical of heavy industry. The integrated lens-cleaning air interface (400 l/min) prevents ash and soot buildup to ensure continuous operation.

FAQs

What is the primary advantage of the LOS model over the FOC version?

The LOS (Line-of-Sight) model offers a simpler installation and higher signal sensitivity because it lacks fiber-optic components. It is ideal for burners where the scanner can be mounted with a direct, straight-line view of the flame.

Does this scanner require cooling air?

Yes. You must provide a continuous lens-cleaning airflow of 400 l/min (14 SCFM). This air supply maintains a positive pressure (300 mm H₂O above windbox) to keep the optics clear of debris and provide essential cooling for the scanner tip.

How does the SF810INT-LOS-UV-T-L handle different fuel types?

The SiC photodiode is sensitive to the 280 nm UV peak found in the combustion of natural gas, fuel oils, coal, and sulfur gas. You can calibrate the scanner's sensitivity and frequency filters via the local 4-button interface to match the specific characteristics of your fuel.

Is this part interchangeable with the F810I-LOS-UV-TL-C-W?

The part numbers refer to the same high-specification UV scanner assembly within the SF810 series. We confirm that this unit is 100% Brand New and meets all original ABB factory specifications for industrial flame safety.

ABB SF810INT-LOS-UV-T-L | SIL-Rated Industrial Flame Monitor

Item no : 59669503733
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 18 - Jul 23

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches