20% OFF shipping at terrelite.it on orders over $79 + up to 10% OFF products
terrelite.it
home > K7214 HIMA F-Series Datasheet & Technical Manual > K7214 HIMA F-Series Datasheet & Technical Manual
download picture
K7214 HIMA F-Series Datasheet & Technical ManualHIMA K7214 F Series Control Panel Module The HIMA K7214, also cataloged as the K7214 Digital I O & Fuse Distribution Module, operates as a dedicated hardware component for feeding and current distribution tasks within F Series Safety System platforms. Hardware Specifications Parameter Specification Model K7214 Brand HIMA Origin Germany Module Type Digital I O & Fuse Distribution Module Operating Voltage 24 VDC 48 VDC (SELV or PELV system compatible)
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

HIMA K7214 F-Series Control Panel Module

The HIMA K7214, also cataloged as the K7214 Digital I/O & Fuse Distribution Module, operates as a dedicated hardware component for feeding and current distribution tasks within F-Series Safety System platforms.

Hardware Specifications

Parameter Specification
Model K7214
Brand HIMA
Origin Germany
Module Type Digital I/O & Fuse Distribution Module
Operating Voltage 24 VDC / 48 VDC (SELV or PELV system compatible)
Current Distribution Up to 150 A total current capacity
Circuit Protection Slots Up to 12 or 18 single circuit breaker positions (E-T-A compatible)
Digital Inputs 8 channels, 24 VDC
Digital Outputs 8 channels, 24 VDC (Short-circuit protected)
Integrated Filtration 2 x Z6015 network filters with monitoring relays
Power Dissipation <= 35 W maximum
Operating Temp -25 to +60 deg C
Dimensions 19-inch rack-mounted width x 2 units high (approx. 48.2 x 8.8 x 17.0 cm)
Weight 1.2 kg to 3.25 kg (Variant and circuit breaker load dependent)

Galvanic Isolation and Fail-Safe State Execution

The K7214 architecture implements hardware-level galvanic isolation between distinct input, output, and current distribution branches to uphold strict safety instrumentation parameters. The distribution grid manages up to 150 A total current across single circuit breakers linked to dedicated front decoupling heat sinks. Internal passive network filters monitor voltage stability parameters continuously through isolated neutral contact paths; an external or local voltage drop drops the relay monitoring contacts immediately. This mechanical circuit break forces adjacent safety control loops to execute their predefined fail-safe state execution sequences, disconnecting localized power grids to eliminate single-point failure hazards.

Frequently Asked Questions

Q: What are the exact grounding restrictions if the physical feeding line distance to the K7214 input terminals exceeds a 0.5-meter run?

A: For power lines exceeding a 0.5-meter physical run, screened feeding lines are required. The continuous metal shield must be bound to the chassis ground plate to intercept and divert electromagnetic transients before they interact with the internal filter relays.

Q: Can single E-T-A circuit breaker modules be extracted or replaced on the front mounting plate while the panel is live?

A: No. Individual branch load lines must be de-energized prior to modifying circuit breakers. Removing a breaker under active high-current loading can induce electrical arcing across the socket receiver blocks, damaging the terminal paths.

Q: How does the module handle fault signaling if an internal digital output channel encounters a direct short-circuit?

A: The digital output subsystem features independent short-circuit protection circuits. When an overcurrent threshold is crossed, the local channel trips off and the integrated monitoring relays open, triggering an ungrounded neutral diagnostic alarm to the main controller.

Field Installation Guidelines

  • 19-Inch Subrack Alignment: Align the structural frame ears with the standard 19-inch rack tracking profiles (IEC 297 specifications). Install and tighten all four panel fasteners to ground the front plate to the cabinet framework.
  • Cable Inlet Proximity Rule: Mount the panel module near the primary cabinet cable inlets. This minimizes the length of internal high-current distribution runs and avoids noise induction across adjacent low-voltage analog signal tracks.
  • Circuit Breaker Seating Verification: Insert the selected E-T-A circuit breakers firmly into their designated front-accessible slot sockets. Inspect the locking alignment to guarantee robust mechanical retention against low-frequency industrial plant vibration.
  • Neutral Contact Monitoring Loops: Wire the onboard voltage monitoring neutral contacts directly into the supervisory ESD loop logic. Use separate terminal paths to prevent field noise from shifting the logic reference point.

K7214 HIMA F-Series Datasheet & Technical Manual

Item no : 61456856313
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 20 - Jul 25

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches