20% OFF shipping at terrelite.it on orders over $79 + up to 10% OFF products
terrelite.it
home > 5501-467 Woodward MicroNet Series Datasheet & Technical Manual > 5501-467 Woodward MicroNet Series Datasheet & Technical Manual
download picture
5501-467 Woodward MicroNet Series Datasheet & Technical ManualWoodward 5501 467 MicroNet Simplex Main Power Supply Module The Woodward 5501 467, also cataloged as the 5501 467 Main Power Supply, operates as a dedicated hardware component for delivering regulated DC power within MicroNet Simplex platforms. Hardware Specifications Parameter Specification Model 5501 467 Brand Woodward Origin USA Weight 2. 32 kg (5. 11 lbs) Dimensions 7. 5 cm x 24. 6 cm x 26. 1 cm Operating Temp 0 to +60 deg C Power Consumption
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Woodward 5501-467 MicroNet Simplex Main Power Supply Module

The Woodward 5501-467, also cataloged as the 5501-467 Main Power Supply, operates as a dedicated hardware component for delivering regulated DC power within MicroNet Simplex platforms.

Hardware Specifications

Parameter Specification
Model 5501-467
Brand Woodward
Origin USA
Weight 2.32 kg (5.11 lbs)
Dimensions 7.5 cm x 24.6 cm x 26.1 cm
Operating Temp 0 to +60 deg C
Power Consumption Power conversion limits up to 531 W (DC) / 1062 VA (AC)
24 Vdc Input Range 18 to 36 Vdc (20-32 Vdc nominal)
120 Vac/dc Input Range 88-132 Vac (47-63 Hz) / 100-150 Vdc
Max Input Current (24 Vdc) 29.5 A
Max Input Current (120 Vac) 12.1 A
Holdup Time 5 ms @ 24 Vdc / 1 Cycle @ 120 Vac
Diagnostic Indicators Input Fault, Power Supply Fault, Overtemperature, OK
Fuse/Breaker Requirements 50 A Time Delay (24 V) / 20 A (120 V)

Industrial Drives, Governors, and Speed Control Properties

The power module performs direct energy conversion to feed processing units and variable geometry actuators linked to the electronic governor network. The design integrates a specialized 1-cycle ride-through holdup circuit at 120 Vac to suppress momentary grid voltage drops, preventing unintended processor resets that disrupt actuator loop feedback response routines. To withstand localized electrical disturbances inherent to heavy industrial power grids, the module features built-in harmonic distortion suppression stages and heavy-duty industrial shielding. Internal heat sink dissipation profiles are calibrated to sustain maximum power outputs of 531 W under continuous operations within hot turbine cabinet enclosures.

Frequently Asked Questions

Q: What are the discrete line isolation behaviors when running a dual-input configuration?

A: The internal switching architecture manages distinct voltage inputs separately. It accepts low-voltage 24 Vdc or high-voltage 120 Vac/Vdc standards, protecting the central MicroNet backplane components from line transients via internal galvanic boundaries.

Q: How does the power supply handle localized thermal overloads?

A: The device monitors its internal thermal thresholds via self-diagnostic circuitry. If internal limits are exceeded, the hardware trips the front-panel Overtemperature indicator LED and modulates or shuts down its output states to protect internal component groups.

Q: What are the exact protective fusing requirements for the distinct input lines?

A: For the 24 Vdc input loop, a 50 A time-delay fuse or circuit breaker is required. For the 120 V input circuit, the line must be protected by a 20 A rated branch circuit breaker or fuse.

Field Installation Guidelines

  • Chassis Grounding and Shield Integrity: Ensure the module is mechanically locked into the MicroNet chassis frame using the designated mounting hardware. Direct chassis metal-to-metal contact is mandatory to establish an optimal ground path for the heavy-duty industrial shielding and internal noise filters.
  • Input Power Wiring Disconnects: External power routing must include dedicated, accessible circuit breakers or fuses sized per the 50 A (24 V) or 20 A (120 V) specifications. Use separate conduit entries for high-voltage 120 Vac/Vdc and low-voltage 24 Vdc lines to mitigate mutual inductive interference.
  • Thermal Management Ventilation: Mount the chassis in an orientation that permits unhindered vertical convection through the power supply ventilation slots. Maintain the ambient cabinet temperature below +60 deg C to prevent the activation of the internal overtemperature safety trip.

5501-467 Woodward MicroNet Series Datasheet & Technical Manual

Item no : 715749281
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 17 - Jul 22

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches