home > CP401-10 Yokogawa | 10kHz Pulse Input Processor Module > CP401-10 Yokogawa | 10kHz Pulse Input Processor Module
download picture
CP401-10 Yokogawa | 10kHz Pulse Input Processor ModuleProduct Overview The Yokogawa CP401 10 serves as a high integrity gateway and processing interface for CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS). This module executes two critical roles: it facilitates high speed data exchange between the DCS core and third party subsystems, and it provides specialized hardware for 10kHz pulse input acquisition. We supply this unit as 100% Brand New and Original, specifically designed for
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Overview

The Yokogawa CP401-10 serves as a high-integrity gateway and processing interface for CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS). This module executes two critical roles: it facilitates high-speed data exchange between the DCS core and third-party subsystems, and it provides specialized hardware for 10kHz pulse input acquisition. We supply this unit as 100% Brand New and Original, specifically designed for continuous 24/7 operation in demanding oil & gas, chemical, and power generation environments.

Technical Specifications

Parameter Details
Manufacturer Yokogawa Electric Corporation
System Compatibility CENTUM VP, CENTUM CS 3000
Pulse Input Frequency 0 to 10 kHz (High-Speed Acquisition)
Signal Type Contact ON/OFF, Voltage Pulse, Current Pulse
Min Pulse Width 40 ms
Isolation 500 VAC (Channel-to-System)
Power Input 24 VDC (±10%)
Current Consumption 0.5A @ 24 VDC
Redundancy Supports Redundant FCS Nests
Protocol Integration Modbus/TCP, EtherNet/IP, Profibus, Vnet/IP
Storage/Backup Dual Memory Card Slots (Backup & Logging)
Operating Temp 0 °C to +55 °C
Weight 0.8 kg

Engineering Advantages

  • Precision Pulse Acquisition: The CP401-10 processes high-speed signals up to 10kHz. This allows direct interfacing with flowmeters and rotating machinery sensors without requiring separate high-speed counter modules. It eliminates signal lag, providing the DCS with real-time totalization and speed data.

  • Protocol Bridging Efficiency: This module translates complex industrial protocols—including Modbus/TCP and EtherNet/IP—into Yokogawa's proprietary Vnet/IP deterministic network. It streamlines cabinet architecture by acting as a single-point gateway for diverse third-party PLC and analyzer data.

  • Industrial Hardening & Isolation: The module features 500 VAC isolation between channels and the system backplane. This electrical barrier prevents field-side surges from damaging the expensive Field Control Station (FCS) processor cards, ensuring high system survival rates in electrically noisy environments.

  • Data Integrity Protection: Dual onboard memory card slots facilitate automatic configuration backups and local historical logging. If the system loses network connectivity or primary power, the CP401-10 preserves critical process parameters and totalized values for bumpless recovery.

FAQs

Q: Can the CP401-10 replace a standard communication card in a legacy CS 3000 rack?

A: Yes. The CP401-10 maintains physical and electrical compatibility with standard Yokogawa FCS nests. It provides a superior upgrade path by adding high-speed pulse processing capabilities to standard communication functions.

Q: Does this module require an external power supply for the pulse inputs?

A: The CP401-10 operates on 24 VDC. While the module processes the signals, you must ensure the field transmitters provide the appropriate voltage or current pulses within the signal compatibility range (Voltage, Contact, or Current).

Q: How does redundancy work with the CP401-10?

A: You can install the CP401-10 in a redundant FCS nest. The system synchronizes data across the redundant pair, allowing the standby module to assume control instantly if the active unit detects an internal fault or communication timeout.

Q: What is the benefit of the Style/Revision S2 on Yokogawa modules like this?

A: While the base model handles standard tasks, revisions like Style S2 typically incorporate updated internal components and improved thermal management to meet the latest global safety and EMC standards.

Do you need to integrate this module with a specific third-party protocol like Modbus or EtherNet/IP?

CP401-10 Yokogawa | 10kHz Pulse Input Processor Module

Item no : 73281363859
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 18 - Jul 23

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches