Endress+Hauser Proline Prosonic Flow G500 9G5B Ultrasonic FlowmeterOverview Highly robust gas specialist for fluctuating process conditions as remote version with up to 4 I Os. Specs at a glance Max. measurement error Volume flow (standard): 1. 0 % o. r. for 3 to 40 m s (9. 84 to 131. 23 ft s) 2 % o. r. for 0. 3 to 3 m s (0. 98 to 9. 84 ft s) Volume flow (optional calibration): 0. 5 % o. r. for 3 to 40 m s (9. 84 to 131. 23 ft s) 1. 0 % o. r. for 0. 3 to 3 m s (0. 98 to 9. 84 ft s) Corrected volume flow (standard):
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Overview 

Highly robust gas specialist for fluctuating process conditions as remote version with up to 4 I/Os.
Specs at a glance
Max. measurement error
Volume flow (standard):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Volume flow (optional calibration):
‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (standard):
‐ ±1.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (optional calibration):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Sound Velocity: ±0.2 % o.r.
Measuring range
Gas: 0.3 m/s to 40 m/s
Medium temperature range
-50 to 150 °C (-58 to +302°F)
-50 to 100 °C (-58 to +212°F) with integrated pressure cell
Max. process pressure
0.7 to 101 bar a (10.15 to 1464.88 psi a)
Wetted materials
Measuring tube: 1.4408/1.4409 (CF3M)
Transducer: 1.4404 (316, 316L, Titan Grade 2

Application

For a wide range of gas applications Prosonic Flow G provides reliable flow measurement, even with wet gas and changing gas properties and compositions. A pressure-rated sensor housing with rupture disc limits safety risks. The innovative remote transmitter maximizes installation flexibility and operational safety in demanding nvironments. Heartbeat Technology ensures compliance and process safety at all times.
* The measuring principle is unaffected by gas composition
* Accurate measurement of natural and process gas in the chemical as well as oil and gas industries. Device properties:
* Direct measurement: flow, pressure & temperature
* Wetted parts: titanium / 316L
* Maximum measuring accuracy: 0.5 %
* Remote version with up to 4 I/Os
* Backlit display with touch control and WLAN access
* Standard cable between sensor and transmitter

Benefits

* Flexible device with user-definable gas mixtures for demanding measuring tasks
* Maximum reliability even with humid or wet gas – sensor design insensitive to condensate
* High-performance process control – real-time pressure- and temperature-compensated values
* Efficient solution – multivariable, no pressure loss
* Full access to process and diagnostic information – numerous, freely combinable I/Os
* Reduced complexity and variety – freely configurable I/O functionality
* Integrated verification – Heartbeat Technology

Specification 

item
value
Warranty
1 Year
Customized support
OEM
Place of Origin
Germany
Brand Name
Endress+Hauser
Model Number
Prosonic Flow G300
Type
Ultrasonic flow meters
Product Headline
Highly robust gas specialist for fluctuating process conditions as remote version with up to 4 I/Os.
Flexible device with user-definable gas mixtures for demanding measuring tasks.
Accurate measurement of natural and process gas in the chemical as well as oil and gas industries.
Sensor Features
Maximum reliability even with humid or wet gas – sensor design insensitive to condensate. High-performance process control –
real-time pressure- and temperature-compensated values. Efficient solution – multivariable, no pressure loss.
Direct measurement: flow, pressure & temperature. Wetted parts: titanium / 316L. Maximum measuring accuracy: 0.5 %.
Transmitter Features
Full access to process and diagnostic information – numerous, freely combinable I/Os. Reduced complexity and variety – freely
configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and
transmitter.
Nominal Diameter Range
DN 25 to 300 (1 to 12")
Wetted Materials
Measuring tube: 1.4408/1.4409 (CF3M)
Transducer: 1.4404 (316, 316L, Titan Grade 2
Measured Variables
Volume flow, corrected volume flow, mass flow, flow velocity, speed of sound, pressure, temperature, density, dynamic viscosity,
energy flow, Wobbe index, methane fraction, calorific value, molar mass
Max. Measurement Error
Volume flow (standard):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Volume flow (optional calibration):
‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (standard):
‐ ±1.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (optional calibration):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Sound Velocity: ±0.2 % o.r.
Measuring Range
Gas: 0.3 m/s to 40 m/s
Max. Process Pressure
0.7 to 101 bar a (10.15 to 1464.88 psi a)
Medium Temperature Range
-50 to 150 °C (-58 to +302°F)
-50 to 100 °C (-58 to +212°F) with integrated pressure cell
Ambient Temperature Range
-40 to 60 °C(-40 to +140 °F)
Optional: -50 to 60 °C(-58 to +140 °F)
Sensor Housing Material
Stainless Steel, 1.4404(316/316L), 1.4408/1.4409 (CF3M)
Transmitter Housing Material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
Polycarbonate
Degree Of Protection
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation
4-line backlit display with Touch Control (operation from outside)
Configuration via local display and operating tools possible
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs
Status input
4-20 mA input
Digital Communication
HART, Modbus RS485
Power Supply
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous Area Approvals
ATEX, IECEx, cCSAus, JPN, EAC, UK Ex, KC
Product Safety
CE, C-tick
Functional Safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological Approvals And Certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
Pressure Approvals And Certificates
PED, CRN
Material Certificates
3.1 material
NACE MR0175/MR0103


Endress+Hauser Proline Prosonic Flow G500 9G5B Ultrasonic Flowmeter

Item no : 79284953675
sold recently : Login >>
US$ 1781.25
Pay in 4 interest-free payments of $445.31 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 24 - Jul 29

Enjoy 20% off shipping

US$ 1781.25

1-11

US$ 1603.12

12-35

US$ 1246.88

36-59

US$ 1068.75

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches