20% OFF shipping at terrelite.it on orders over $79 + up to 10% OFF products
terrelite.it
home > FBM207B Foxboro P0914WH I/A Series Datasheet & Technical Manual > FBM207B Foxboro P0914WH I/A Series Datasheet & Technical Manual
download picture
FBM207B Foxboro P0914WH I/A Series Datasheet & Technical ManualFoxboro FBM207B P0914WH Fieldbus Module The Foxboro FBM207B, also cataloged as the FBM207B Analog Input Fieldbus Module, operates as a dedicated hardware component for field transmitter interfacing within I A Series DCS networks. Configured for high density physical signal acquisition, the Foxboro FBM207B P0914WH processes 16 isolated analog channels concurrently, driving real time digitization of loop currents directly via the system backplane
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Foxboro FBM207B P0914WH Fieldbus Module

The Foxboro FBM207B, also cataloged as the FBM207B Analog Input Fieldbus Module, operates as a dedicated hardware component for field transmitter interfacing within I/A Series DCS networks. Configured for high-density physical signal acquisition, the Foxboro FBM207B P0914WH processes 16 isolated analog channels concurrently, driving real-time digitization of loop currents directly via the system backplane interface. The hardware runs localized analog-to-digital conversion parameters to offload raw processing tasks from the primary system controllers.

Hardware Specifications

Parameter Specification
Model FBM207B (P0914WH)
Brand Foxboro (Schneider Electric)
Origin United States
Weight 0.4 kg
Dimensions 25 cm x 6.2 cm x 15 cm
Operating Temp -20 to +60 deg C
Power Consumption 24 V DC via system backplane
Channel Capacity 16 analog input channels
Input Signal Types 4-20 mA current loops
Resolution 12-16 bit A/D conversion
Isolation Channel-to-channel and channel-to-ground
Update Rate Deterministic scan cycle, configurable
Diagnostics Built-in monitoring of open/short circuits, signal integrity
Enclosure Rating IP20 (Cabinet installation required)
Certifications CE, UL, cUL, ATEX compliant

Process Control & DCS Instrument Characteristics

The FBM207B structural design features hardwired conditioning loops optimized to sustain the 4-20 mA HART loop protocol across all 16 integration points. The internal board routing implements strict channel-to-channel isolation barriers, preventing stray ground loop current propagation from shifting concurrent loop measurement baselines. When processing mixed analog networks, this electrical isolation maintains terminal stability against high-frequency electromagnetic noise, preserving physical data properties for cold junction compensation (CJC) cross-referencing on adjacent high-density sensor networks.

Frequently Asked Questions

Q: What are the physical constraints when executing a hot-swap replacement of the FBM207B?

A: The module supports live backplane removal and insertion under power. The mechanical baseplate keys align matching pins before power contacts touch, preventing transient bus reflection or noise on adjoining active cards during hot-swap execution.

Q: How does the internal hardware manage an unexpected field-side short circuit?

A: Each channel contains independent over-current sensing. If a short circuit occurs, the affected channel limits current loops internally to protect internal A/D converter components while updating the system diagnostic word.

Q: Does the P0914WH module require an external power supply for 4-20 mA loop excitation?

A: No. Loop power is distributed directly from the system backplane through the isolated channel circuits of the FBM207B, eliminating the need for independent external distribution rails inside the cabinet.

Field Installation Guidelines

  • Enclosure Environmental Controls: Secure the module onto the matching I/A Series baseplate structure inside a sealed IP54 or NEMA Type 12 cabinet. Maintain unhindered vertical ventilation paths to prevent localized thermal accumulation below the chassis boundary.
  • Shield Grounding Matrix: Terminate all field transmitter cable shield drains at the central instrument ground bus-bar. Never ground a single shield at both the field device and the enclosure terminals to eliminate parasitic ground loop currents.
  • Cable Pathway Separation: Separate all 4-20 mA instrumentation lines from AC power distribution conduits. Maintain a minimum physical clearance of 300 mm inside the wiring trays to suppress inductive noise coupling.
  • Conductor Mechanical Termination: Ensure field conductors match the 12-22 AWG specification of the paired termination block. Strip wire ends to exactly 7 mm and secure the screw terminals to factory-defined torque limits to prevent contact resistance variation.

FBM207B Foxboro P0914WH I/A Series Datasheet & Technical Manual

Item no : 88076993068
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 22 - Jul 27

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches