Endress+Hauser 9P5B Proline Prosonic Flow P500 Ultrasonic Clamp-on FlowmeterOverview Endress+Hauser Proline P500 Ultrasonic Clamp on Flowmeter is a Reliable, flexible, zero maintenance noninvasive flow measurement, consistently accurate, even under challenging conditions. Specs at a glance * Max. measurement error Volume flow: 3% o. r. for DN 15 2% o. r. for DN 25 to DN 200 2% o. r. above DN 200 * Measuring range 0 to 15 m s (0 to 50 ft s) * Medium temperature range DN 15 to 65 (to 2"): 40 to +150C (40 +302 F) DN 50 to 4000
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Overview

Endress+Hauser Proline P500 Ultrasonic Clamp-on Flowmeter is a Reliable, flexible, zero maintenance – noninvasive flow measurement, consistently accurate, even under challenging conditions.

Specs at a glance

* Max. measurement error
Volume flow:
±3% o.r. for DN 15
±2% o.r. for DN 25 to DN 200
±2% o.r. above DN 200
* Measuring range
0 to 15 m/s (0 to 50 ft/s)
* Medium temperature range
DN 15 to 65 (½to 2½"): –40 to +150°C (–40 +302 °F)
DN 50 to 4000 (2 to 160"): –40 to +170°C (–40 to +338 °F)
DN 50 to 600 (2" to 24"): 150°C to 550°C (+302 to +1022 °F)
* Max. process pressure
N/A 
 

Field of application

Prosonic Flow P 500 is the ultrasonic clamp-on flowmeter of choice for safe and maintenance-free measurement of conductive and non-conductive liquids, even in challenging applications. It measures flow noninvasively and idirectionally, independent of pressure, density and conductivity, and without process interruption.
FlowDC makes mounting as flexible as never before. The specified accuracy is maintained at an inlet run of only 2 x DN, even in the case of disturbed flow profiles.
Special coupling pads make this ultrasonic clamp-on system maintenance-free during the entire product life cycle.

In addition, Prosonic Flow P 500 is available with:
* high-temperature sensors for measurement up to 550 °C (1022 °F) 
* a Petroleum Application Package (PAP), calculating the standard volume for liquid hydrocarbons 
* Heartbeat Technology, providing continuous process transparency. This way, build-up can be detected before it affects operation 
 

Benefits

 * Flexible mounting – FlowDC reduces inlet runs to a minimum
* High safety standards – Prosonic Flow P 500 is developed according to IEC 61508 functional safety requirements and holds international approvals for hazardous area, Zone 1 and Class I, Division 1
* Reliable measurement performance – proven sensors in combination with maintenance-free mounting system deliver long-term stable signals, also in high-temperature applications (≤550 °C/1022 °F)
* User-friendly operation – the web server offers full remote access, while the device’s touch display offers convenient on-site interaction
* Transparent process insights – Heartbeat Technology with its integrated diagnostics, verification and monitoring functions enable compliance and process safety at all times
* Low capital investment – cost-effectiveness increases with the pipe diameter (up to DN 4000/160") 
 

Specification

item value
Warranty 1 Year
Customized support OEM
Place of Origin Germany
Brand Name Endress+Hauser
Model Number Prosonic Flow P500
Type Ultrasonic flow meters
Product Headline Clamp-on flowmeter for limited spaces in process industries with up to 3 I/Os. 
Constant accuracy even when mounted with short inlet run thanks to FlowDC. 
Bidirectional measurement of various fluids, e.g. liquid hydrocarbons and chemicals.
Sensor Features High safety standards – SIL by design, 
international hazardous area approvals. Long-term stable signal – maintenance-free 
permanent mounting from outside with coupling pads. Reliable measurement on various pipe materials – sensor for GRP and plastic 
pipes available. 
Mounting without process interruption. Wide nominal diameter range: DN 15 to 4000 (½ to 160"). Medium temperature: –40 to +550 °C 
(–40 to +1022 °F).
Transmitter Features Full access to process and diagnostic information – numerous, freely combinable I/Os. Reduced complexity and variety – 
freely configurable I/O functionality. Integrated verification – Heartbeat Technology. 
Remote version with up to 3 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and 
transmitter.
Nominal Diameter Range Dual channel, 1 or 2 paths : DN 15 to 4000 (1/2 to 160")
Sensor Materials Clamp on system: 
Sensor holder 1.4301/304, 1.4404/316L 
Sensor housing 1.4301/304, 1.4404/316L 
Strapping bands 1.4301/304, 1.4404/316L
Measured Variables Volume flow, sound velocity, flow velocity, totalizer
Max. Measurement Error Volume flow: 
±3% o.r. for DN 15 
±2% o.r. for DN 25 to DN 200 
±2% o.r. above DN 200
Measuring Range 0 to 15 m/s (0 to 50 ft/s)
Max. Process Pressure N/A
Medium Temperature Range DN 15 to 65 (½to 2½"): –40 to +150°C (–40 +302 °F) 
DN 50 to 4000 (2 to 160"): –40 to +170°C (–40 to +338 °F) 
DN 50 to 600 (2" to 24"): 150°C to 550°C (+302 to +1022 °F)
Ambient Temperature Range –40 to +60 °C (–40 to +140 °F) 
–50 to +60 °C (–58 to +140 °F) optional
Sensor Housing Material N/A
Transmitter Housing Material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
Degree Of Protection Sensor remote version: IP68 type 6P 
Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control(operation from outside) 
Optional: WLAN 
Configuration via local display and operating tools possible
Outputs 3 outputs: 
4-20 mA HART (active/passive) 
4-20 mA (active/passive) 
Pulse/frequency/switch output (active/passive) 
Double pulse output (active/passive) 
Relay output
Inputs Status input 
4-20 mA input
Digital Communication HART, Modbus RS485
Power Supply DC 24 V 
AC 100 to 230 V 
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous Area Approvals ATEX, FM/CSA, EAC, UK Ex, KC
Product Safety CE, C-tick, EAC-marking
Functional Safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological Approvals And Certificates Flowmeter verification for all frequencies except 0.3 MHz, reference line size: 5 MHz DN 50, all other frequencies DN 100 
Verification performed on accredited calibration facilities (acc. to ISO/IEC 17025) 
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a

 

Endress+Hauser 9P5B Proline Prosonic Flow P500 Ultrasonic Clamp-on Flowmeter

Item no : 97328221507
sold recently : Login >>
US$ 2062.50
Pay in 4 interest-free payments of $515.62 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 25 - Jul 30

Enjoy 20% off shipping

US$ 2062.50

1-11

US$ 1856.25

12-35

US$ 1443.75

36-59

US$ 1237.50

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

"Beau"

US$ 125.00

Min. order: 1 piece

4.4 (59 reviews)

Sold : Login>>

Related Searches