20% OFF shipping at terrelite.it on orders over $79 + up to 10% OFF products
terrelite.it
home > LI-220C Com-Power LISN New > LI-220C Com-Power LISN New
download picture
LI-220C Com-Power LISN NewAdditional Features: Frequency range of 9 kHz to 30 MHz Fully compliant with CISPR 16 1 2 ANSI C63. 4 Air core inductors to prevent saturation Individual Calibration Included Three Year Warranty General Specifications Application: Power Line Conducted Emissions Tests Standards: CISPR 16 1 2, ANSI C63. 4 Type: 50 50 H + 5 (CISPR), 50 H & 250 H (ANSI) Frequency Range: 9 kHz to 30 MHz Insertion Loss (Voltage Division Factor): 9 kHz 150 kHz <6. 5 dB to
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Additional Features:

  • Frequency range of 9 kHz to 30 MHz
  • Fully compliant with CISPR 16-1-2 / ANSI C63.4
  • “Air-core” inductors to prevent saturation
  • Individual Calibration Included
  • Three-Year Warranty

General Specifications

  • Application: Power Line Conducted Emissions Tests
  • Standards: CISPR 16-1-2, ANSI C63.4
  • Type: 50Ω / 50 μH + 5Ω (CISPR), 50 μH & 250 μH (ANSI)
  • Frequency Range: 9 kHz to 30 MHz
  • Insertion Loss (Voltage Division Factor): 9 kHz - 150 kHz <6.5 dB to <0.5 dB (increasing linearly with log of freq); 150 kHz - 30 MHz <0.5 dB
  • Isolation: 9 kHz - 150 kHz >10 dB to >60 dB (increasing linearly with log of freq); 150 kHz - 30 MHz >60 dB

Electrical Specifications

  • Voltage Rating: 270 VoltsAC (rms), 380 VoltsDC (Line to Ground)
  • Current Rating: 20 AmpsAC (rms), 14 AmpsDC
  • Input/Output Connectors
  • EUT Power Input Port: IEC C20 Receptacle
  • EUT Power Output Port: Universal Multi-Configuration AC Receptacle
  • RF Measurement Port: 50Ω - N-Type (female)

Mechanical Specifications

  • Dimensions: (H)x(W)x(D) 7.5” x 17” x 15.35” (19 x 43 x 39 cm)
  • Weight: 20.5 lbs (9.3 kg)

Environmental Specifications

  • Operating Temperature: 40°F to 104°F (5°C to 40°C)

The LI-220C Line Impedance Stabilization Network (LISN) provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products. The LI-220C is compliant with both CISPR 16-1-2 and ANSI C63.4. The LISN provides defined stable impedance and isolates the EUT from power source influences, thereby providing accurate and repeatable results. The LI-220C includes one pair of single-conductor networks, housed together, to be installed in series with each current-carrying conductor in a single- phase, dual-phase or DC power system. A second LI-220C pair can be used to accommodate 3-phase power systems (Wye or Delta configurations).

This LISN uses air-core inductors to prevent saturation and permeability variation. The mounting plate of the LI-220C is left unpainted in order to facilitate connection to earth ground in its installation, which is essential due to high leakage current. Use of a Transient Limiter for impedance matching, reduction of out-of-band emissions and transient protection for your measurement instrument is highly recommended and available from Com- Power. All Com-Power LISNs are individually calibrated in compliance with the relevant requirements of CISPR 16-1-2 and ANSI C63.4. Impedance, Phase, Isolation, and Insertion Loss data is supplied with each unit, along with the calibration certificate.

The LI-220C Line Impedance Stabilization Network (LISN) is in full compliance with both CISPR 16-1-2 and ANSI C63.4. It provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products. The LI220C performs each of the following functions during the measurement:

  • Provides a defined, stable impedance across the measurement frequency range
  • Isolates the EUT and measurement circuit from the power source, thereby minimizing its influence on the measurements
  • Couples the disturbance voltages to the coaxial measurement port for connection to the measuring instrument.

This LISN uses air-core inductors to prevent saturation and permeability variation. The mounting plate of the LI-220C is left unpainted in order to facilitate connection to earth ground in its installation, which is essential due to high leakage current.

Versatility

The LI-220C is a dual-conductor network capable of handling currents up to 20 Amps(AC) per line. The EUT power port is fitted with a universal, multi-configuration receptacle, which accommodates almost any EUT plug without the need for adapters. The power input port is fitted with a standard IEC C20 receptacle.

Transient Protection

Com-Power Transient Limiters are a recommended accessory in order to protect the RF input of your measuring instrument from potentially damaging, instantaneous voltage transients. The transient limiter also reduces the possibility of overload by incorporating two 5 dB attenuation/impedance matching pads, in addition to its low-pass and high-pass filter sections which further attenuate any out-of-band emissions.

Calibration

All Com-Power LISNs are individually calibrated in compliance with the relevant requirements of CISPR 16-1-2 and ANSI C63.4. Impedance, Phase, Isolation, and Insertion Loss data is supplied with each unit, along with the certificate of calibration. Recognized ISO 17025 accredited calibration is also available upon request.

The Com-Power LI-220C replaces the LI-220A.

LI-220C Com-Power LISN New

Item no : 24614411354
sold recently : Login >>
US$ 1775.00
Pay in 4 interest-free payments of $443.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 24 - Jun 29

Enjoy 20% off shipping

US$ 1775.00

1-11

US$ 1597.50

12-35

US$ 1242.50

36-59

US$ 1065.00

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches